| MODEL |
Unit |
GL11000TM |
| Type |
- |
Rotating field single-phase AC Generators |
| Frequency |
Hz |
60 |
| Standby Output |
kVA (kW) |
11.0 (11.0) |
| Prime Output |
kVA (kW) |
10.0 (10.0) |
| Voltage - Single Phase |
V |
120/240 |
| Armature Connection |
- |
Series |
| Phase / Wire |
- |
1/3 |
| Power Factor |
- |
1.0 |
| No. of Poles |
- |
2 |
| Insulation |
Class |
Rotor coil; class F, Stator coil; class B |
| Type of Coupling |
- |
Direct coupled |
| AMPS |
| Single Phase 120V |
A |
83.4 |
| Single Phase 240V |
A |
41.7 |
| NO. OF RECEPTACLE |
| 5-15R (GFCI) |
- |
N/A |
| 5-20RA (GFCI) |
- |
1 |
| 6-15R |
- |
N/A |
| TERMINAL |
| Terminal |
- |
Available |
| DIESEL ENGINE |
| Type |
- |
Vertical, liquid-cooled,
4-cycle diesel engine |
| Model |
- |
D722 |
| No. of Cylinders |
- |
3 |
| Bore x Stroke |
mm (in.) |
67.0 x 68.0 (2.6 x 2.7) |
| Displacement |
L (cu. in.) |
0.719 (43.9) |
| Engine Speed |
rpm |
3600 |
| Continuous Rated Output |
kW (HP) |
12.2 (16.3) |
Lubricant
(API classification) |
- |
above CF grade |
| Oil Capacity |
L (qts.) |
3.4 (0.9) |
| Coolant Capacity |
L (qts.) |
4.1 (1.1) |
| Starting System |
- |
Electric - 12 volt DC |
| SET |
| Fuel |
- |
Diesel fuel No.2
(ASTM D975) |
Fuel
Consumption |
at Full Load |
L/h (gal./h) |
4.1 (1.09) |
| at 3/4 Load |
L/h (gal./h) |
3.3 (0.86) |
| at 1/2 Load |
L/h (gal./h) |
2.7 (0.71) |
| at 1/4 Load |
L/h (gal./h) |
2.2 (0.59) |
| Fuel Tank Capacity |
L (gal.) |
28.0 (7.4) |
Continous
Operation
Hours |
at Full Load |
h |
7.0 |
| at 3/4 Load |
h |
8.5 |
| at 1/2 Load |
h |
10.4 |
| at 1/4 Load |
h |
12.7 |
| Battery (Ah/5h) |
- |
55B24R (12V x 36Ah) |
Dimensions
L x W x H |
mm
(in.) |
1281 x 618 x 698
(50.4 x 24.3 x 27.5) |
| Approx. Net Weight |
kg (lbs.) |
295 (650) |
Sound Level
(Full Load at 23 ft. [7m]) |
dB (A) |
68 |
| Emergency Stop System |
- |
In case of abnormal: Oil pressure, water temperature, or When the access terminal cover is opened (terminal type only) |